Automatic Self-testing of
Emergency Lighting

Once installed, P4 emergency lighting luminaires, fire safety signs and conversions of mains luminaires will automatically self-test on a regular basis in compliance with BS EN 50172/BS 5266 Part 1 requirements.

In the unlikely event that system communications are interrupted, fittings revert to Fastel Standalone operation, which ensures continuing compliance with the Regulatory Reform (Fire Safety) Order 2005.

Removing the need for manual testing provides significant cost savings and enables facilities management resources to be more effectively used elsewhere. Payback of the investment is typically achieved within 2-3 years and through life cost is considerably reduced.

For medium or larger premises Fastel Link or Fastel Wireless addressable technologies can provide remote monitoring and control. With internet access, the emergency lighting system can be monitored and administered from anywhere in the world using a laptop, tablet or smart phone. All of our LED luminaires and exit signs are provided with P4’s unique ten-year product and battery warranty.

How It Works

  • Standalone fully automatic self-testing emergency lighting in accordance with ATS type PERC classification, as classified by BS EN 62034.
  • Luminaires and signs incorporate self-contained emergency lighting operation with built-in standalone self-testing in accordance with ATS type S, as classified by BS EN 62034.
  • Luminaires and signs automatically carry out testing in excess of the requirements of BS EN 1838/BS 5266 Part 1.
  • A self-testing programme embedded in the microprocessor built into the inverter/driver modules automatically initiates and controls tests of the emergency lighting unit and provides status indication through a single multi-function bi-colour LED indicator.
  • A sounder in control modules operates for 10 seconds every hour until the fault is rectified to reinforce fault indication. The sounder may be deleted as an order option.
  • Nominal Test Cycle – To ensure that adjacent units do not test simultaneously, all test sequences programmed into the integral microprocessor controllers are randomly set during production to test up to +12 hours from a nominal eight-day cycle
Emergency lighting LED indicator

Wired System:
Fastel Link

P4’s Fastel Link is a robust, fully addressable self-testing emergency lighting system. The modular system allows for simple expansion or upgrading of the existing lighting network into new areas. New versions of equipment are backward compatible, so there will be no need to replace the existing system when carrying out future works.

Specification

  • Fastel Link enabled fittings are all connected by a simple wired bus communications network to the M-Web FWSD Central Supervision Unit.
  • Up to 63 CB/FWS DUO Collector Boxes can be connected back to the M-Web FWSD by a 2 core Master bus with a nominal 28v d.c.
  • Fastel Link compatible fittings are connected to the M-Web FWSD or a CB/FWS DUO using a 2 core Luminaire Bus with a nominal 28v d.c.
  • The Master bus and Luminaire bus wiring is not polarity specific and if wired in the recommended cable type, can be run in the general electrical containment systems with a maximum cable run of 2,000 metres.

 

Fastel Mesh Technology (FMT) System:
Fastel Wireless

Fastel Mesh Technology (FMT) enables fully addressable self-testing emergency lighting to be installed in all types of premises without the need for bus wiring between luminaires. Wireless systems can connect the full range of interior and exterior self-testing luminaires and signs, using a self-healing wireless mesh communication network to ensure secure communications with no single point of failure.

FMT is an ideal solution for premises and areas where it is difficult to install additional wiring such as:

  • heritage buildings
  • buildings that are continuously occupied
  • buildings where access to install bus wiring is difficult
  • buildings or areas with solid ceilings
  • buildings or areas that are remote from one another.

It may be more cost effective to install a FMT solution rather than adding communications wiring to existing installations. FMT supports full integration of wired and wireless communications.

FMT Schematic

P4 Cloud

Compatible with all M-Web FWSD controllers* P4 Cloud provides an intuitive user interface enabling customers to control and monitor their wired or wireless Fastel emergency lighting system. 

  • Connection via standard internet connection or GSM
  • Continually updated
  • Downloadable test records
  • System status alerts
  • Accessible from any internet connected device
  • No single point of failure – all testing records are stored locally on the M-Web controller unit as well as the P4 Cloud
  • Enables P4 to assist customers with training and remote maintenance if required.**

* Firmware update may be required.
** Subject to P4 remote monitoring contact.

P4 Cloud

Light Angel

Light Angel (LA) is an application based wireless emergency lighting monitoring and control system.

  • Application downloadable from Google Play Store
  • 100 fittings per installation, multiple installations possible per site
  • Up to 52 weeks of test results saved internally within luminaires
  • Customisable testing schedules
  • Automatic wireless meshing communication system
  • Light Angel tablet available on request.
Light Angel tablet

Key
Products

M-Web FWSD

The M-Web FWSD is a central supervision unit with an embedded web server which continuously scans your whole installation. It’s capable of sending control data to connected devices and gathering information about their status.

Read more >>

CB/FWS Duo

The CB/FWS DUO Collector Box is an intermediate data relay and collection unit. It exchanges data with an M-WEB FWSD.

Read more >>

RPT/FWS

The RPT/FWS Repeater Unit allows secure communication and expansion of the M-Web FWSD. It’s able to communicate with up to 15 Fastel Wireless equipped emergency luminaires or signs.

Read more >>

EAS

The EAS module allows alarms from static inverters and central battery systems to be monitored within your Fastel system.

Read more >>

GSM

The GSM router is a dual SIM 3G/4G/LTE router, designed with a metal housing for use in a wide range of site-based applications. Offering primary WAN or 3G/LTE failover to fixed line connections. Its small size is ideal for remote monitoring and control.

Read more >>

MIM

The new M-WEB Integration Module (MIM) Central Supervision Unit, complete with OLED screen display.

Read more >>